Refrigerator interior lights may stay on when the doors are closed or fail to turn on when a door is opened.

Part number: 6871JB1423NAppliance brand: LG3 customer repair reports

Common Symptoms

The refrigerator interior lights may stay on after the doors are closed, or they may not turn on when a door is opened. These symptoms can have more than one cause.

What to Check

Start with the light bulbs and door switches. One repair involving lights that would not turn on included replacing the bulbs and checking that the door micro switches worked before the control board was replaced. If those basic checks do not explain the problem, the switch circuit, wiring, and control board may need model-specific diagnosis.

When the Control Board May Be Involved

The control board was replaced in repairs for both lights staying on and lights that would not turn on, and normal lighting was reported afterward. That does not prove the board is the cause in every refrigerator with a lighting problem. Confirm the diagnosis and verify that part 6871JB1423N is compatible with your refrigerator before ordering.

Before Replacing the Board

Disconnect power before inspecting internal components. A board replacement involves electrical connections, so use a qualified technician if you are unsure or need electrical diagnosis.

Possible Causes

Possible causes include the light bulbs, door switches, wiring, or the control board’s light-control circuit. In one repair, replacing bulbs and checking the door switches did not resolve lights that would not turn on; replacing the control board was followed by working lights. Another repair involving lights staying on also reported normal operation after a board replacement, but the cause was not confirmed independently.

What to Check

Check whether the bulbs are good and whether the door switches appear to operate normally. If the lights remain on with the doors closed or stay off after these checks, the issue may need model-specific diagnosis of the switch circuit, wiring, and control board. Disconnect power before inspecting internal components; use a qualified technician for electrical diagnosis.

Repair note: These troubleshooting details summarize reported repair experiences. Symptoms can have more than one cause. Disconnect power before inspecting electrical components, and use a qualified technician when a repair involves hazardous voltage or uncertain wiring.