Common Symptoms
An LG washer with this problem may stop during a cycle and not turn back on, have a blank display, or become unresponsive after a breaker trips. In one repair, the washer intermittently locked up during the rinse cycle before eventually failing to power on.
What to Check
- Check whether the household breaker has tripped and whether the washer has power at its outlet.
- Note when the washer became unresponsive and whether the problem began after a breaker trip or during a cycle.
- If the washer has power but the controls remain dead, arrange model-specific diagnosis before ordering a control board.
When the Control Board May Be Involved
A failed main control board is a possible cause when the washer has power but its display or controls do not respond. Some repairs associated with this symptom included replacing the board and restoring operation. That outcome does not confirm that every washer with a blank display or shutdown has a bad board. A breaker trip or another washer or electrical problem may also be involved.
Before Replacing the Board
Confirm the replacement board is compatible with the washer's full model number. Disconnect power before inspecting internal components, and use a qualified technician for electrical diagnosis or board checks.
Possible Causes
A failed main control board is one possibility; replacement was followed by successful operation in some repairs. A breaker trip or another electrical or washer problem can also cause a loss of power, so the board should not be assumed defective without diagnosis. One repair also found a loose agitator center nut, though its role in the control-panel failure was uncertain.
What to Check
Check whether the household breaker has tripped and whether the washer has power at its outlet. Note whether the display is blank, the washer stopped during a cycle, or the breaker tripped. If power is present but the washer remains unresponsive, have the washer diagnosed using the procedures for its exact model. Disconnect power before inspecting internal parts; use a qualified technician for electrical diagnosis.