LG washer blows a fuse or will not drain during the cycle

A washer repeatedly blew a fuse around draining and later did not switch on the drain pump during rinse. The repair included replacing the pump and then the control board.

Part number: EBR86771812Appliance brand: LG1 customer repair reports

Common Symptoms

The washer may blow a fuse during draining, or it may fail to start the drain pump during rinse. A fuse that keeps blowing needs diagnosis rather than repeated resets.

What to Check

Stop using the washer if the fuse continues to blow. Note whether the problem occurs during draining or rinse, and have the drain system and its controls checked. The pump, wiring, and control board can require model-specific diagnosis; the symptom alone does not identify the failed part.

When the Control Board May Be Involved

In one repair, replacing the pump did not resolve the problem: the washer still would not activate the drain pump during rinse. The control board was replaced afterward, and the washer worked. This repair sequence does not prove that the board is responsible for other fuse-blowing or draining problems.

Before Replacing the Board

Confirm compatibility with your washer's exact model before ordering EBR86771812. Disconnect power before inspecting internal components, and use a qualified technician for electrical diagnosis.

Possible Causes

A fuse blowing during draining can have more than one cause. In one repair, the pump was replaced, but the washer still would not activate the drain pump during rinse; the control board was then replaced and the washer worked afterward. This does not establish that the board is the cause of every fuse or draining problem.

What to Check

Stop repeatedly resetting a fuse that continues to blow. Note when the problem occurs and have the pump, wiring, and control system checked using model-specific procedures. Disconnect power before inspecting internal components; use a qualified technician for electrical diagnosis.

Repair note: These troubleshooting details summarize reported repair experiences. Symptoms can have more than one cause. Disconnect power before inspecting electrical components, and use a qualified technician when a repair involves hazardous voltage or uncertain wiring.