Refrigerator side not cooling

The refrigerator compartment is not cooling properly; an evaporator fan may run continuously.

Part number: W11449482Appliance brand: Whirlpool2 customer repair reports

Common Symptoms

The refrigerator side is not cooling, even though the evaporator fan may be running. Poor cooling can also occur alongside a defrost problem, so check for frost buildup and assess the defrost system rather than assuming the fan or control board is at fault.

What to Check

Check the fan and relevant defrost components according to the diagnostic procedure for your refrigerator model. One repair involving a warm refrigerator side included checks of the heater, thermistor, and fan before the control board was replaced. Another reported that the refrigerator began cooling after the board was replaced, but did not describe diagnostic checks.

When the Control Board May Be Involved

A control-board replacement was followed by improved cooling in individual repairs, but this does not prove that the board is the cause of every no-cooling problem. Confirm the diagnosis and verify that W11449482 fits your exact model before ordering.

Disconnect power before inspecting internal components. Use a qualified technician for electrical diagnosis.

Possible Causes

Possible causes include a problem with the fan or defrost system, or another model-specific cooling fault. One repair reported checking the heater, thermistor, and fan before replacing the control board; another reported improved cooling after a board replacement without describing diagnostic checks. The board is not confirmed as the cause in every case.

What to Check

Note whether the fan runs and whether the refrigerator side is warm. Check the fan and defrost components using model-specific instructions; the reported checks included the heater, thermistor, and fan. If the cause is unclear, have the refrigerator diagnosed before replacing the board. Disconnect power before inspecting internal components and use a qualified technician for electrical diagnosis.

Repair note: These troubleshooting details summarize reported repair experiences. Symptoms can have more than one cause. Disconnect power before inspecting electrical components, and use a qualified technician when a repair involves hazardous voltage or uncertain wiring.