The air conditioner may begin to cool, then beep or flash and stop, or it may briefly display “88” before going dark. One reported unit also stopped blowing cold air unless its button was held down.

Part number: WJ26X238795 customer repair reports

Common Symptoms

An air conditioner with this problem may start to cool and then stop, beep, or flash. It may not stay running, or its display may briefly show “88” before going dark. One reported unit began acting this way after a storm-related power outage and would cool only while its button was held down.

These symptoms can have more than one cause. The display observation alone does not establish what has failed.

What to Check

  • Confirm the air conditioner’s exact model number and check compatibility for WJ26X23879 before ordering.
  • Note the sequence of symptoms: whether the unit starts, beeps or flashes, stops cooling, or goes dark. Record any displayed characters, including “88.”
  • Consult model-specific troubleshooting guidance and consider other possible causes before deciding the control board needs replacement.

When the Control Board May Be Involved

A board replacement was followed by normal operation in reported repairs involving beeping or flashing and failure to cycle on. Another repair reported unplugging and reconnecting the board when the unit would not stay running. These outcomes show that the board was involved in those particular repairs, but they do not prove that every air conditioner with these symptoms has a faulty board.

Before Replacing the Board

Verify the part against the full model number and the existing board’s identifying information. Disconnect power before inspecting internal components, and use a qualified technician for electrical diagnosis. Do not force open metal panels or fasteners; have a technician handle access if the unit cannot be opened safely.

Possible Causes

These symptoms can have more than one cause, and the available details do not establish a universal diagnosis. In one repair, the air conditioner began working after WJ26X23879 was replaced; another repair also reported success after replacing the board. A separate unit that would not stay running was addressed by unplugging and reconnecting its board, but the repair details do not confirm why that helped. Check model-specific troubleshooting information and other possible causes before concluding the board has failed.

What to Check

Confirm the exact air conditioner model and that the replacement board is compatible; compare the existing control panel and part information rather than relying on appearance alone. Note whether the unit beeps, flashes, displays “88,” goes dark, or stops cooling, and whether the symptom began after a power outage. Consult the model’s troubleshooting guidance and check other possible causes before replacing the board. Disconnect power before inspecting internal components. Use a qualified technician for electrical diagnosis.

Related error code: 88 (display observed; meaning not established)