Common Symptoms
The refrigerator cools inconsistently, the compressor sometimes does not start after power-up, or the freezer repeatedly warms enough to thaw food and then cools again.
What to Check
Pay attention to whether the problem affects both compartments and whether it follows a power interruption. Repeated thawing can put food at risk, so move perishable food to reliable cold storage and arrange service if temperatures are not being maintained.
When the Control Board May Be Involved
In some repairs with these symptoms, replacing the main control board was followed by normal operation. One intermittent-cooling repair also involved starter relays, with only temporary improvement before the board was replaced. These details do not make the board a certain cause: compressor-starting and temperature-control faults can have more than one explanation.
Have a qualified technician diagnose the appliance before ordering WR55X46945. Disconnect power before inspecting internal components; electrical diagnosis should be handled by a qualified technician.
Possible Causes
A main control board replacement was followed by restored operation in repairs involving intermittent cooling and repeated thawing and refreezing. In one intermittent-cooling repair, replacing starter relays gave only minor temporary improvement before the board was replaced. These accounts do not prove the board is the cause in every case; compressor-starting and cooling problems need diagnosis.
What to Check
Record when cooling stops and whether the refrigerator, freezer, or both are affected. If food is thawing, protect it and arrange service promptly. Because the reported symptoms can have multiple causes, use model-specific diagnosis before replacing the board; do not attempt electrical testing unless qualified.