242104302 - Frigidaire Refrigerator Inverter Board Replacement

Replace the inverter board with the refrigerator unplugged and water supply shut off. The compressor must be shifted to access the board; after installing and reconnecting the replacement, restore the compressor, rear panel, water line, and power.

Part number: 242104302 · Brand: Frigidaire

This guide covers replacing refrigerator inverter board part number 242104302. The supplied information does not identify a specific refrigerator model, so confirm part fitment for your appliance before starting.

Tools and supplies

  • 1/4-inch socket or nut driver
  • Phillips-head screwdriver or number 2 square-drive bit
  • Flat-head screwdriver

Before you begin

  • Unplug the refrigerator before beginning and keep it disconnected while accessing or replacing the inverter board.
  • Shut off the water supply before disconnecting the line at the inlet valve.
  • The inverter board is part of the refrigerator’s electrical system. If you are not qualified to work on appliance electrical components, have a qualified technician perform the repair. Do not test live circuits.

Step-by-step instructions

  1. Disconnect power and water — Unplug the refrigerator. Shut off its water supply before working at the rear of the appliance.
  2. Remove the rear access panel — Use a 1/4-inch socket or nut driver to remove the screw holding the water-line retainer to the rear panel. Detach the water line from the inlet valve, then remove the remaining panel screws and set the panel aside.
  3. Shift the compressor and disconnect the board — Pull off the compressor’s three retaining pins and remove the washers. Carefully lift the compressor and move it to the right. Disconnect the two inverter-board wire connectors. With a 1/4-inch socket or nut driver, remove the grounding-wire screw. Use a Phillips-head screwdriver or a number 2 square-drive bit to remove the screw securing the inverter board to the compressor. Use a flat-head screwdriver to release the wire connector from the compressor terminals, then remove the old board.
  4. Fit and connect the replacement board — Position the replacement board behind the refrigerant lines, to the left of the compressor. Slide its wire connector onto the compressor terminals and hook the board onto the compressor. Reinstall and tighten the board-retaining screw, secure the grounding wire with its screw, and reconnect the two inverter-board wire connectors.
  5. Return the compressor and close the rear panel — Reposition the compressor and board. Put the washers in place and secure the compressor with its three retaining pins. Reposition the rear access panel and fasten it with the screws. Reconnect the water line to the inlet valve and secure it to the rear panel with the retainer and screw.
  6. Restore services and check the refrigerator — Turn the water supply back on, then plug in the refrigerator. Check around the water-line connection for leaks and confirm the refrigerator powers up and operates normally.

After the repair

Restore the water supply and plug the refrigerator back in. Check the reconnected water line and inlet valve area for leaks, then confirm the refrigerator powers up and operates normally.

Repair safety: Disconnect power before working on internal parts. Follow the service instructions for your exact appliance model. Contact a qualified technician for hazardous electrical or gas-system work.