Use this sequence only if the board and range are confirmed compatible. The supplied part number is 8523666; it is a lookup identifier and does not by itself confirm fitment.
Tools and supplies
- Pliers
Before you begin
- Unplug the range before beginning and keep it disconnected until reassembly is complete.
- If the range is hardwired or you are unsure how to isolate power safely, have a qualified appliance technician perform the repair.
Step-by-step instructions
- 1. Disconnect power and remove the rear panel — Unplug the range. Remove the top rear panel to access the clock control board.
- 2. Disconnect the ribbon cable — Remove the ribbon wire from the connector attached to the board. Note its routing and orientation so it can be reinstalled the same way.
- 3. Release the old control board — Use pliers to twist the retaining tabs that hold the board to the control panel, then remove the board.
- 4. Position and secure the replacement board — Place the replacement board against the control panel and secure it with the retaining tabs.
- 5. Transfer the wires and reconnect the ribbon — Move the wires from the old board to the corresponding connections on the replacement board. Insert the ribbon wire into its connector and snap the connector into place.
- 6. Reassemble and check operation — Reinstall the top rear panel, then plug the range back in. Check that the clock control powers up and functions normally.
After the repair
Confirm the rear panel is secure and the ribbon and transferred wires are seated. Restore power and check the clock control for normal operation. If it does not function properly, disconnect power and consult a qualified appliance technician.
Repair safety: Disconnect power before working on internal parts. Follow the service instructions for your exact appliance model. Contact a qualified technician for hazardous electrical or gas-system work.