W10366605 - How to Replace a Whirlpool Refrigerator Defrost Control Board

Replace the defrost control board by unplugging the refrigerator, lowering the control panel, transferring the wires to the replacement board, and reinstalling the panel before restoring power.

Part number: W10366605 · Brand: Whirlpool · Model: Not specified in the repair instructions. ED5VHEXTQ01 appears in the related catalog product title, but fitment is not confirmed here.

This guide covers the control-panel access and board replacement sequence described for this repair. Check your refrigerator’s model information and the replacement part’s fitment before beginning; the part number alone does not confirm compatibility.

Tools and supplies

  • Screwdriver

Before you begin

  • Unplug the refrigerator before starting and keep it disconnected while working on the wiring.
  • If you are not qualified to work on appliance electrical components, have a qualified technician perform the repair.

Step-by-step instructions

  1. 1. Disconnect power and remove the control panel — Unplug the refrigerator. Remove the screws securing the control panel, then pull the panel forward to release it.
  2. 2. Move the panel aside for access — For better access, you may disconnect the grounding wire and crisper-light wire connector. If you disconnect these, remove the screw securing the damper control arm so the arm is not damaged while the panel is moved.
  3. 3. Remove the old board — Remove the screws holding the defrost control board. Note the wire arrangement and orientation, then disconnect the wires and remove the board.
  4. 4. Install the replacement board — Connect the wires to the corresponding terminals, following the arrangement noted during removal. Position the board in the control panel and secure it with its screws.
  5. 5. Reassemble the control panel — Align the slot in the damper control arm with the freezer control cam and reinstall the arm’s screw. Reconnect the crisper-light wire connector and attach the grounding wire to the heat shield if they were disconnected. Align the control panel with its mounting tabs, push it into place, and reinstall the panel screws.
  6. 6. Restore power and check operation — Plug the refrigerator back in and confirm that it is functioning properly.

After the repair

With the control panel secured and power restored, check that the refrigerator is operating properly. If it does not, unplug it again and have the wiring and installation checked by a qualified technician.

Repair safety: Disconnect power before working on internal parts. Follow the service instructions for your exact appliance model. Contact a qualified technician for hazardous electrical or gas-system work.