This procedure describes replacing the noise filter board in a built-in microwave. The listed model is KMBP100ESS01; confirm the replacement part is appropriate for your appliance before starting. Because microwave components can retain hazardous voltage even after power is disconnected, have a qualified appliance technician handle internal electrical work if you are not trained to do so.
Tools and supplies
- Phillips-head screwdriver or 1/4-inch nut driver
- T-10 Torx bit
- Assistant to help move the microwave
Before you begin
- Turn off power to the microwave at the oven junction box before beginning. Do not work on the appliance while it is energized.
- Microwave capacitors can retain dangerous voltage after power is disconnected. Internal electrical repairs should be performed by a qualified appliance technician; do not attempt to discharge a capacitor yourself.
- The built-in microwave is heavy. Use an assistant when removing or reinstalling it, and set it on a sturdy surface.
- If the conduit is too short to move the microwave, disconnecting its power and grounding wires at the junction box is required by the procedure. Have a qualified person do this work if you are not equipped and trained to handle the wiring.
Step-by-step instructions
- 1. Disconnect power and clear the microwave — Switch off power to the microwave at the oven junction box. Open the door and remove the racks, turntable, and turntable support.
- 2. Remove the microwave from the cabinet — Remove the two screws securing the mounting flanges to the cabinet, and take out the washers if they remain in place. With an assistant, carefully slide the microwave out and set it on a sturdy surface. If the conduit does not allow enough movement, have a qualified person disconnect the power and grounding wires and remove the conduit from the junction box.
- 3. Open the top access panel — Remove the four panel screws using a Phillips-head screwdriver or 1/4-inch nut driver. Lift the panel, then slide it forward to remove it.
- 4. Remove the old noise filter board — Note how the wires are arranged on the board, then disconnect them. Press the retaining tab to release the grounding wire. Use a T-10 Torx bit to remove the two board mounting screws, then lift out the old board.
- 5. Install the replacement board and reconnect the wiring — Align the new board on the blower and secure it with the two mounting screws. Reconnect the wires to their corresponding terminals, following the arrangement noted during removal. Reattach the grounding wire to the frame.
- 6. Close the access panel and reinstall the microwave — Fit the panel by inserting its rear edge first, then secure it with its screws. With an assistant, return the microwave to the cabinet and push it into position. Place the washers in the mounting-flange holes, then reinstall the two cabinet screws.
- 7. Restore the interior parts and power — Replace the turntable support and align the turntable on the coupling. Restore power at the junction box only after the microwave is fully reassembled.
After the repair
Check that the microwave is seated securely in the cabinet, the mounting screws are in place, and the turntable is aligned on its coupling. Once power is restored, confirm the appliance powers on normally. If it does not, switch power off and contact a qualified appliance technician.