Free shipping & taxes included on all orders
Step-by-step repair guide

W10808108 - How to Replace the Control Board in a Jenn-Air Wine Cellar

This procedure covers access to the control board behind the base grille, removal and installation of the board, and reassembly. Disconnect the wine cellar from power before beginning.

Part number: W10808108 · Brand: Jenn-Air · Model: JUW24FRECX00 and JUW24FRECX130 (models named in the source; fitment is not independently verified)

The source identifies Jenn-Air wine cellar models JUW24FRECX00 and JUW24FRECX130. Confirm the replacement board fits your exact model before installing it.

Tools and supplies

  • Phillips-head screwdriver
  • Needle-nose pliers

Before you begin

  • Unplug the wine cellar before removing panels or disconnecting wiring. Do not work on the appliance while it is connected to power.
  • The appliance may be heavy, have sharp edges, and contain fragile components. Handle the grille and control board carefully.

Step-by-step instructions

  1. 1. Disconnect power and remove the base grille — Unplug the wine cellar. Use a Phillips-head screwdriver to remove the two screws securing the base grille. If the grille remains caught, press the tabs near its top to release it, then pull the grille away.
  2. 2. Remove the control board cover and disconnect the wiring — Remove the screws holding the control board cover and take off the cover. Note how the wires are oriented before disconnecting their connectors from the existing board.
  3. 3. Remove the old board and install the replacement — Use needle-nose pliers to detach the old control board from its mounting posts. Align the replacement board with the posts and press it into place until it snaps on. Reconnect the wire connectors to the corresponding terminals, following the orientation you noted.
  4. 4. Refit the cover and grille — Reposition the control board cover and secure it with its retainer. Align the base grille with its brackets and reinstall the two mounting screws.
  5. 5. Restore power and check operation — Plug the power cord back in and check that the wine cellar powers on and operates normally.

After the repair

Confirm the grille and control board cover are secure, then verify that the wine cellar powers on and operates normally. If it does not, unplug it and recheck the wiring connections and board fit; seek qualified service if the problem remains.

Repair safety: Disconnect power before working on internal parts. Follow the service instructions for your exact appliance model. Contact a qualified technician for hazardous electrical or gas-system work.