Replace the ice-level emitter board by unplugging the refrigerator, removing the emitter housing and its two screws, fitting the new board, and reinstalling the assembly and ice bin.

Part number: W10870822 · Brand: KitchenAid · Model: KRMF706ESS01

These instructions describe the board replacement procedure for a KitchenAid five-door refrigerator identified in the source as model KRMF706ESS01. Confirm the replacement part fits your exact model before starting; the part number alone does not establish compatibility.

Tools and supplies

  • Putty knife
  • Phillips-head screwdriver

Before you begin

  • Unplug the refrigerator before removing the emitter assembly or disconnecting its wiring.
  • Handle the ice bin and components carefully; edges may be sharp, and the bin may be heavy.
  • Do not work on energized wiring. If the repair requires work beyond the unplugged, low-voltage emitter assembly, contact a qualified appliance technician.

Step-by-step instructions

  1. Disconnect power and access the ice bin — Unplug the refrigerator. Open the refrigerator door and remove the ice bin so you can reach the emitter assembly in the ice-bin housing.
  2. Release the emitter housing — Use a putty knife to press the upper retaining tab, then carefully release the emitter board housing from the ice-bin housing.
  3. Disconnect and remove the old board — Disconnect the wire connector from the emitter assembly. With a Phillips-head screwdriver, remove the two mounting screws securing the old board to its housing, then lift the board away.
  4. Install the replacement board — Position the replacement board on the housing and reinstall the two mounting screws to secure it. Reconnect the wire connector.
  5. Reinstall the assembly and ice bin — Align the emitter assembly with the ice-bin housing and snap it into place. Reinstall the ice bin and close the refrigerator door.
  6. Restore power and check operation — Plug the refrigerator back in. Check that the emitter assembly remains seated and the ice bin is in place. Confirm ice-level sensing and normal ice-maker operation according to the refrigerator's use and care instructions.

After the repair

If the assembly will not stay seated, the connector does not fit, or ice-level sensing does not operate normally, unplug the refrigerator again and recheck the installation and part fit. Consult the model's documentation or a qualified appliance technician if the issue remains.