These instructions describe a control-board replacement. Confirm that the part matches your refrigerator before starting; the part number shown is an identifier, not confirmation of fitment.
Tools and supplies
- 1/4-inch socket or nut driver
- Needle-nose pliers
Before you begin
- Unplug the refrigerator before opening the control-board compartment. Do not work on the appliance while it is connected to power.
- If you are unsure how to handle the wiring or grounding connection, have a qualified appliance technician do the repair.
Step-by-step instructions
- 1. Disconnect power and open the access panel — Unplug the refrigerator. Use a 1/4-inch socket or nut driver to remove the screws holding the control-board access panel, then set the panel aside.
- 2. Record and disconnect the wiring — Before removing any wires, note or photograph how each connector is positioned on the board. Disconnect the connectors, then detach the grounding wire from the refrigerator frame.
- 3. Remove the old board — Use needle-nose pliers to squeeze the tabs on the board’s mounting pins and release the board. Lift it away from the pins.
- 4. Install the replacement board and reconnect wires — Align the replacement board with the mounting pins and press it into place until it snaps on. Reconnect each wire connector to the corresponding terminal, following the positions you recorded.
- 5. Refit the panel and secure the ground — Reinstall the access panel. Secure the grounding wire with the upper-left access-panel mounting screw, then fasten the remaining panel screws.
- 6. Restore power and check operation — With the panel secured, plug the refrigerator back in. Check that it powers up and operates normally.
After the repair
Confirm the access panel is firmly secured and the grounding wire is attached beneath the upper-left panel screw. After restoring power, verify that the refrigerator starts and operates normally.
Repair safety: Disconnect power before working on internal parts. Follow the service instructions for your exact appliance model. Contact a qualified technician for hazardous electrical or gas-system work.